Por favor, use este identificador para citar o enlazar este ítem: http://repositorio.unach.edu.pe/handle/UNACH/42
Título : Development and preliminary validation of an automatic digital analysis system for animal fibre analysis
Autor : Quispe Bonilla, Max David
Benavidez Caballero, Freddy Gianfranco
Sauri Ibañez, Roberth Andre
Bengoechea Irañeta, José Javier
Quispe Peña, Edgar Carlos
Palabras clave : Ingeniería Eléctrica y Electrónica
Fecha de publicación : 2-oct-2017
Editorial : Universidad Nacional Autónoma de Chota
Resumen : New equipment was designed and developed to evaluate the physical characteristics of animal fibres, based on an automatic digital analysis system (ADAS) that allows the capture of a series of real-time images. In the development of the mechanical component, a design tool was used that allows visualization, simulation, and documentation of the product. At the same time, an Atmel (ATmega328) microcontroller was programmed to enable displacement of table coordinates, focus of images, and reading of the temperature and humidity of fibre samples and the environment. The fibre images were processed using artificial vision technology. Algorithms were also developed for edge detection to define the diameter of the fibre in pixels. Finally, calibration was carried out using a regression and standardized samples of wool tops. The authors then weighted the pixels to μm with a standard sample. A friendly graphical interface was developed for management of the built equipment, visualization of results, calibration, data and graphic export, configuration, among others. For validation, average fibre diameter (AFD), standard deviation (SD), coefficient of variation and comfort factor (CF) were compared with values of top wool patterns. Finally, the measurements of OFDA 2000 and FIBER-EC were compared using student t-test and Pearson correlation. The results of the validation showed that the confidence limit of FIBER-EC, which varied between 0.075 and 3.47 μm, is similar to that of the confidence limit of Sirolan Laserscan and OFDA 2000. Accuracy is better than the OFDA 2000 for fibre assessments less than 25 μm, which vary between 0.034 and 0.250 μm.
URI : http://repositorio.unach.edu.pe/handle/UNACH/42
ISSN : 2221-4062
Aparece en las colecciones: Artículos científicos publicados en revistas indizadas

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
Articulo13.pdf721,14 kBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.